Prihoda Journal

Knowledge bank

Insulated Fabric Ducting: Keeping Conditioned Air at the Right Temperature

Conditioned air does not always travel directly from the air handling unit to the point where it is supplied. It may first pass through ceiling voids, roof spaces, plenums, service areas or other parts of a building that are not temperature-controlled. During this journey, the air can gain or lose heat. As a result, it may reach the supply point at a different temperature than originally intended. This can reduce the cooling or heating effect, increase system running time and create a risk of condensation in humid environments.

Prihoda insulated fabric ducting addresses this issue by integrating thermal insulation directly into the duct construction. Instead of adding a separate layer of external insulation, the insulation is placed between two textile layers, creating a lightweight and practical solution for conditioned air transfer.

How does insulated fabric ducting work?

The insulated air duct consists of three main layers:

Outer textile layer

The outer layer can be selected to match the appearance of the surrounding fabric ducting system. It is available in different colours and can also include custom branding, printed graphics or other designs created using PRIHODA ART.

Integrated insulation layer

A layer of fire-resistant, non-woven polyester insulation is positioned between the outer and inner fabrics. It is available in nominal thicknesses of 10 mm, 20 mm or 30 mm, allowing the duct construction to be adapted to the thermal requirements of the project.

Smooth inner layer

The inner layer is made from Prihoda’s lightweight, non-permeable textile material. It creates a smooth internal surface through which the air can travel efficiently.

Internal rings help maintain the circular shape of the duct during operation. Individual sections are joined by zippers, making the system easier to install, remove and maintain.

Why insulate an air transfer duct?

The main purpose of insulated fabric ducting is to limit unwanted temperature changes while conditioned air is being transported between the air handling unit and the supply area.

Integrating insulation into the duct itself can help:

  • reduce heat gain or heat loss during air transport,
  • maintain the required air temperature at the point of delivery,
  • reduce the risk of surface condensation,
  • improve the thermal efficiency of the HVAC system,
  • limit unnecessary system running time,
  • reduce noise in the operating space,
  • keep the ducting lightweight and easy to handle.

Unlike conventional externally insulated ductwork, the textile construction combines the air transfer duct and its insulation in one system. This simplifies handling and installation while retaining the low weight typically associated with fabric ducting.

Where can insulated air ducting be used?

Insulated fabric ducting is primarily intended for the transfer of conditioned air through spaces where the surrounding temperature or humidity could affect the air inside the duct.

Typical applications include:

  • air transfer through roof or ceiling voids,
  • non-conditioned technical and service areas,
  • plenums and headers without air diffusion,
  • humid environments where condensation needs to be reduced,
  • underfloor air transfer systems,
  • long duct sections without air distribution,
  • applications where lower operating noise is beneficial.

It can also be used to connect an air handling unit with fabric diffusers installed in the occupied area.

Air transfer or air distribution?

Insulated ducting is designed primarily for air transfer, meaning that the air remains inside the duct until it reaches the required supply point.

Where air distribution is also needed, additional zipped diffuser sections can be included in the system. These sections can be designed with the appropriate perforations, microperforations or nozzles to distribute air into the occupied space.

This makes it possible to combine insulated air transfer and purpose-designed air distribution within one connected fabric ducting system. PRIHODA fabric ducting can therefore perform different functions within a single HVAC installation, depending on the requirements of each section.

Lightweight construction

The insulation material is designed to provide thermal protection without adding unnecessary weight. Even the 30 mm insulation layer has a maximum weight of approximately 360 g/m².

For example, an insulated circular duct with a diameter of 500 mm and a length of 10 metres weighs no more than approximately 6 kg, excluding the suspension system. The final weight depends on the duct diameter, selected fabric and insulation thickness.

The low weight can make transport, installation and removal for maintenance considerably easier than with many conventional ducting systems.

Important design considerations

PRIHODA insulated fabric ducting is manufactured in a circular shape and is designed for positive-pressure systems. Available diameters start from 250 mm.

The insulation is installed at its nominal thickness, but system pressure partially compresses it during operation. This changes the effective insulation thickness and influences its thermal performance. Operating pressure should therefore be considered when selecting the appropriate insulation depth for a particular project.

The system can be installed using standard PRIHODA suspension methods, including gliders or enlarged cords. Due to handling and weight considerations, the maximum length between individual zipper connections is generally limited to 2,000 mm.

A practical solution for conditioned air transfer

PRIHODA insulated fabric ducting provides a controlled way to transport cooled or heated air without relying on additional external insulation.

By incorporating insulation directly into the textile structure, it helps maintain the required air temperature, reduce condensation risk and simplify installation. The washable construction also supports straightforward maintenance and long-term hygiene.

For complete technical information, including thermal parameters, insulation performance under different operating pressures, installation examples and recommended applications, download the full bulletin here.

you might be also interested
NEW INSTALLATION 

New installation at Will Rogers Memorial Center Arena, Texas

Renovating the HVAC system of a historic arena required a solution that could provide high airflow without placing excessive weight on the existing roof...
Show
Meeting with distributors 

Prihoda around the World: A Production Director’s Trip to Mexico

Irapuato, located in the Mexican state of Guanajuato, is known as the strawberry capital of the world. For Prihoda, however, it has another important meaning...
Show
News 

Prihoda China Moves to a New Factory in Nanjing

Prihoda China has reached an important milestone. In response to growing demand and further production development, the Chinese plant is relocating to a new...
Show
Cookie settings
Information about cookies
Cookies are used to improve websites, to display personalized content and to analyze visitor data. Technical cookies are necessary for the operation of the website - by using the website, you agree to their usege.
Technical cookies
always allowed
They provide key website features such as security, network management, accessibility, and basic traffic statistics. You can turn off technical cookies in your browser settings, but this can negatively affect the functionality of the website.
Performance cookies
They allow you to display relevant content and personalized offers and ads based on your interests on www.prihoda.com, on third-party sites, and on social networks.
Analytical cookies
Third-party tools (such as Google Analytics) allows to improve the way website works with information about usage. Cookies collect this information in a way that does not allow direct identification.
Allow all
Save settings